Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Pinned ideas

PINNED Support of wmts with restful protocol
WMTS tiles in Microstation are only supported in KVP, but not in RESTFUL. As a result, many wmts services cannot be used. There is an urgent need to integrate the restful protocol, as more and more public administration services are only offered v...

General

Showing 554

The "mesure Distance" (Method= Along Element) is bad designed.

MicroStation CE 14 The "mesure Distance" (Method= Along Element) is bad designed when I want to mesure the distance (on the white element) between 2 intersections. To this tool, at least 2 points are needed (the first point must be picked on the e...
over 3 years ago in General 1 Needs review

Publish all updates for Microstation and derivates in all languages simultaneously

I don't understand why it takes ages for Bentley to publish e. g. the update for Microstation Powerdraft so much later than the full Microstation itself - also all localized versions are published weeks, if not months later. I would like to see Mi...
over 3 years ago in General 0 Needs review

Design Script identify and analyze Item Type data

It would be nice to allow a Design Script to identify if an element has an Item Type and some method to interogate the Item Type data in order to change plotting behavior based on the Item Type setting. This could be extended to MS Pen Tables as w...
almost 2 years ago in General 0 Needs review

Checkbox (Select all / unselect all)

MicroStation has a lot of checkbox in the parameters of any Tool Setting dialog but it does not have any checkbox to select the rest of checkbox or unselect all. For example, this would be very valuable in "Change Element Attributes" to check all ...
over 3 years ago in General 0 Needs review

Add the settings for grid lines always are ON

In Microstation, I can display grid lines in the view background, but it disappear if I zoom out too much. Spacings fill by grid lines when the view area is wide too much, so I can understand the reason why. But I think that users should be able t...
11 months ago in General 0 Needs review

ProjectWise File path text substitution in pentable for Connect/ORD

Projectwise does not currently have an easy way to pull the metadata down to give a proper filepath on the PW server when printing. The forums do not seem to have adequate answers on this. There are no variables I can seem to set to make it so I c...
almost 2 years ago in General 0 Needs review

Element Templates in Alphabetical Order

When selecting an Element Template, there does not seem to be a logical order of element templates or folders. It would be much simpler to have all folders and templates in alphabetical order.
almost 2 years ago in General 4 Needs review

Reports - Show only Unique rows option

Hello, I have had issue when using reports that sometimes duplicate rows are shown. For example when I generate the report on a sheet. Then it needs to look in references and not only in the active design file. But on a single sheet maybe there ar...
almost 2 years ago in General 0 Needs review

Selected Elements improved handle manipulation

When selected elements have handles enabled, and those handles are selected again so they show yellow, these can be Translated (moved) as a group. Brilliant.... but I think they should also be able to be edited using the other fundamental modify o...
over 3 years ago in General 1 Needs review

Detail Table - Edit element auto update

When you create a re[ort and select the detail table option to review your report. it would be great if the detail table would auto update once a value has been edited. ATM we have to use the refresh option which also removed the filters
almost 2 years ago in General 3 Needs review