Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Pinned ideas

PINNED Support of wmts with restful protocol
WMTS tiles in Microstation are only supported in KVP, but not in RESTFUL. As a result, many wmts services cannot be used. There is an urgent need to integrate the restful protocol, as more and more public administration services are only offered v...

MicroStation Roadmap

Showing 1647 of 1647

Add Slope Readout to Measure Distance by Points

Add slope display in % and rise over run to the Measure Distance Display. The value would show the slope between the last two data points in the case of multiple point selections
almost 4 years ago in 2D Drawing 0 Future consideration

Select by attributes - add "within highlighted area only" option (i.e. fence)

I know there's the option in the element selection to only search for certain levels etc. but I only get it to work by selecting a bunch of elements and then switching everything off in the various tabs that I don't want to be selected.It would wa...
almost 4 years ago in 2D Drawing 0 Future consideration

graphic group within cell

When creating a named graphic group in a cell definition cell lib and then place it in a drawing (then drop the cell) the graphic group definition is not maintained.The graphic group definition should be maintained after placement.
almost 4 years ago in 2D Drawing 0 Future consideration

In microstation connect edition- explorer, it should be possible to search within a fence.

In microstation connect edition- explorer, itshould be possible to search within a fence. Currently that does not seem to be possible. see this thread for more details;http://communities.bentley.com/products/microstation/f/273/t/116486
almost 4 years ago in General 0 Needs review

Item Type properties should have a Display Label as well as a Name

Most EC schema objects have both a Name and a DisplayLabel. The Name is for MicroStation consumption. The DisplayLabel is for human consumption. The Name may have certain (unpublished) restrictions. The DisplayLabel can be anything: MicroStation d...
almost 4 years ago in General 1 Future consideration

Make the Change Dimension tool work properly on Notes

The change dimension tool has never worked correctly on notes. If I want to change a note or bunch of notes to a different style I've always had to re make every single note. This is very time consuming having to edit sometimes hundreds of notes f...
3 months ago in 2D Drawing 0 Needs review

Add Config Variable to Allow (None) Picklist value to be displayed blank

In our drawing title block, we have a pick list to specify which geographical area the drawing belongs too. We do have some cases where the drawing is related to the whole site, and in those cases, we leave the value blank. I understand some clien...
3 months ago in 2D Drawing 0 Needs review

Table Seed Advanced Settings

Microstation gave us the Advanced Settings option when placing a table from Reports. However, I don't think these settings are very useful here. If I needed them changed, I would have to change them every time I place the desired report. If these ...
6 months ago in General 0 Needs review

A search tool for all dialog boxes with levels in.

Currently setting up some element templates and having to scroll through a long list of levels to select the required one. It would be helpful to have a search tool to assisting in finding specifc level. This would be useful in any dialog box were...
6 months ago in General 1 Needs review

Last Valid Value used.

I have a cell with an item type that reads an alignment and populates the Station and Offset when in ORD. If that file is opened in MSCE and the cell is moved, the station/offset will not be updated (as expected) and the "Last Valid Value" is disp...
over 1 year ago in General 3 Planned