Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Pinned ideas

PINNED Support of wmts with restful protocol
WMTS tiles in Microstation are only supported in KVP, but not in RESTFUL. As a result, many wmts services cannot be used. There is an urgent need to integrate the restful protocol, as more and more public administration services are only offered v...

General

Showing 780

Spelling Checker: Ignore All for Session

Hi, I often will use Microstation's Spelling Checker to check multiple dgn files for spelling errors. Some project use unusual callouts that we don't use on any other project, so I do not want to added these callouts to the dictionary. At the same...
8 months ago in General 0 Needs review

Design Script identify and analyze Item Type data

It would be nice to allow a Design Script to identify if an element has an Item Type and some method to interogate the Item Type data in order to change plotting behavior based on the Item Type setting. This could be extended to MS Pen Tables as w...
over 1 year ago in General 0 Needs review

WMS as background Map

Use WMS similar to Bing background map. Now WMS implementation is not easy to use. As WMS are services thy do not integrate well under Raster Manager and xwms approach is outdated. Why not reuse same WMS list from Servers Manager but under View Se...
over 1 year ago in General 0 Future consideration

Cell Library Dialog - Multiple Instances

Finding, comparing, swapping, managing Cells is becoming more and more common even for non CAD admin users... in today's BIM, component oriented working enivironment. The current Cell Library dialog is used 99% of the time as a viewer. Only when a...
about 2 years ago in General 0 Needs review

Add switch statement to Named Expressions

Named Expressions (and derivatives like Item Types expressions) offers IIF condition. In some situations, when more values to be checked (see e.g. this discussion) it leads to nested expressions, that are hard to understand. It would be nice to ha...
over 3 years ago in General 2 Needs review

Create Cell - Retain Option

Similar to AutoCAD, the Create Cell tool should include a Retain 'Cell' in place option. This would speed modeling components in context very much. Model axle, Create Cell, Model Wheel, Create Cell Model axle, Create Cell, Delete Cell geometry, In...
about 2 years ago in General 0 Needs review

Selecting element will highlight the reference and the level inside the level manager

I am currently working on a design file with a very complex reference structure. is there a way I can select object in my model so that it highlights the particular reference in which that objects belong in the reference manager or level manager. ...
almost 3 years ago in General 1 Will not implement

Associate SAVED VIEW NAME with MODEL vs the DGN

Currently, within the same DGN, you can only use a saved view name ONCE. I am suggesting that Microstation uses a hierarchal structure for its saved views whereby the same view name can be used multiple times because the names would be associated ...
about 2 years ago in General 0 Needs review

Remove from KeyIn

Please add the option to remove selected key in from the dialog history.
9 months ago in General 0 Needs review

Replace Nested Cell

The Replace Cell currently needs to work on nested Cells. Current BIM workflows are heavily based on assembly:component modeling. All designs are based on progressive refinement, iteration and LOD based workflows. This means that whatever placed i...
about 2 years ago in General 0 Needs review