Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Pinned ideas

PINNED Support of wmts with restful protocol
WMTS tiles in Microstation are only supported in KVP, but not in RESTFUL. As a result, many wmts services cannot be used. There is an urgent need to integrate the restful protocol, as more and more public administration services are only offered v...

MicroStation Roadmap

Showing 1596 of 1596

Add Tool settings to Copying or Making Direct Attachment Reference files to Preserve Override Settings

When we need to copy a reference file or promote a nested reference file to a direct attachment, it would be very beneficialif there was some tool settings options to include level override settings.I recently had to convert some nested reference ...
almost 4 years ago in Collaboration 1 Needs review

Clash Detection 2.0 - Parameteric Solids Combo

Mstn CE introduces lots of powerful tools. One of them being the new Parametric Solids which have two powerful aspects. They "keep a record of how objects are built. When you change parameters in the element, the element is updated automatically. ...
almost 4 years ago in 3D Modeling 1 Will not implement

Clash Detection 2.0 - DV / Hypermodeling Combo

Bentley's DV / Hypermodeling tools are pretty powerful in and of themselves. It would be a pity if there wasn't any synergy with the Clash Detection tools or workflow.Clash detection is one particular aspect of checking and coordinating informatio...
almost 4 years ago in 3D Modeling 1 Future consideration

Clash Detection 2.0 - Combo with Design History / DesignSync / ISM

Clash detection seems to be a really poorly understood process.Management seem to think that this is a 'static' endgame process where you start out with a high number of clashes, have a meeting to 'bang heads together', get the number reduced, hol...
almost 4 years ago in 3D Modeling 1 Future consideration

Improved Clash Detection

New Clash Detection in Update 14 is great. But performance of clash detection is still lacking in comparison to Bentley's competition.No Clash Detection process should take longer than 1 hour. Testing the new U14 Clash Detection takes over 2 hours...
almost 4 years ago in General 0 Future consideration

Multiple Active References

Transfered from EAP Ideas listIt would be GREAT to allow multiple attachments to be active in the same session...https://communities.bentley.com/products/microstation/f/19565/p/57246/141402.aspx#141402If there was only ONE thing to put on that To-...
almost 4 years ago in General 1 Will not implement

Save layer visibility in xWMS/xWMTS file

It is not possible to set in xWMS configuration file that some layers are not shown by default. Now it appears that it attaches all listed layers from WMS at once. For example if there are multiple orthophotos of same area but with different dates...
almost 4 years ago in General 0 Needs review

Save clipped Raster with crop

There should be option to save clipped rasters with crop. According to helpNote:Because there is no resampling, it is impossible to save a clipped image.But it is not true that pixels can't be changed as there is clearly an option to turn on resam...
almost 4 years ago in General 0 Needs review

Decal Images/textures' in Cells

Transfered from EAP Ideas listI would like to insert images into cells as decals or textures. Bentley has invested a lot of effort in promoting the integration of visualisation into mainstream workflows.Sigange is one one use case where better too...
almost 4 years ago in Visualization 1 Needs review

need Measure minimum distance

Hello,in V8i we get a clear highlighted line to show the minimum distance measure. This is not available in CE anymore. (And on top of that the interference detection tool is also gone in CE !).So please correct the measure minimum distance tool i...
almost 4 years ago in 3D Modeling 3 Needs review