PINNED Support of wmts with restful protocol
WMTS tiles in Microstation are only supported in KVP, but not in RESTFUL. As a result, many wmts services cannot be used. There is an urgent need to integrate the restful protocol, as more and more public administration services are only offered v...

General

Showing 825 of 1659

The "mesure Distance" (Method= Along Element) is bad designed.

MicroStation CE 14 The "mesure Distance" (Method= Along Element) is bad designed when I want to mesure the distance (on the white element) between 2 intersections. To this tool, at least 2 points are needed (the first point must be picked on the e...
over 3 years ago in General 1 Needs review

Publish all updates for Microstation and derivates in all languages simultaneously

I don't understand why it takes ages for Bentley to publish e. g. the update for Microstation Powerdraft so much later than the full Microstation itself - also all localized versions are published weeks, if not months later. I would like to see Mi...
over 3 years ago in General 0 Needs review

save displayset

When selecting elements and using RMC > Displayset Set, it would be interesting to save the Displayset, so later on you can recall it, rather then having to reselect all the items again to isolate them.
11 months ago in General 1 Will not implement

Mismatch on Manage Configuration Name

When you change the name of the Managed configuration, the mismatch alert will not find the new name and find the correct workspace and workset, even if the original workspace and workset exist in the new managed configuration. The file was opened...
11 months ago in General 0 Needs review

Checkbox (Select all / unselect all)

MicroStation has a lot of checkbox in the parameters of any Tool Setting dialog but it does not have any checkbox to select the rest of checkbox or unselect all. For example, this would be very valuable in "Change Element Attributes" to check all ...
over 3 years ago in General 0 Needs review

ProjectWise File path text substitution in pentable for Connect/ORD

Projectwise does not currently have an easy way to pull the metadata down to give a proper filepath on the PW server when printing. The forums do not seem to have adequate answers on this. There are no variables I can seem to set to make it so I c...
almost 2 years ago in General 0 Needs review

Lock Vertex Location in "Modify Element"

Modify toolBox has a button called "Modify Element". If I pick on a vertex and that Vertex= Rounded, then I can edit the Radius of the arc. However, I would like to edit the Radius of the Arc without moving the location of the vertex so I think th...
over 3 years ago in General 1 Will not implement

Add Line Style Scale to Display Style Dialog

MicroStation display styles can change element color, weight, and line style. However, there is not an option to change the line style scale factor. Our CADD standards use a custom line scale factor other than 1.0. We are requesting an enhancement...
11 months ago in General 0 Needs review

Element Templates in Alphabetical Order

When selecting an Element Template, there does not seem to be a logical order of element templates or folders. It would be much simpler to have all folders and templates in alphabetical order.
almost 2 years ago in General 4 Needs review

Reports - Show only Unique rows option