Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Pinned ideas

PINNED Support of wmts with restful protocol
WMTS tiles in Microstation are only supported in KVP, but not in RESTFUL. As a result, many wmts services cannot be used. There is an urgent need to integrate the restful protocol, as more and more public administration services are only offered v...

General

Showing 808

Ref Dialog - Toggle imodel / dgn

Mstn 2024 will apparaently have an option to save directly to an imodel, in addition to .dgn. It would be great to be able to able to switch between dgn and imodel in the Ref dialog, in order to take advantage of any benefits that imodels can prov...
11 months ago in General 0 Needs review

VBA - How to get handles position

Hi, It will be interresting to have a way to get handles position of an object using VBA. This will help : to find element close to the selected element for instance to build an element showing only the enveloppe of a complicated and loud element....
6 months ago in General 1 Needs review

Display Rule - Generate options

When you are setting up a Display Rule, if you use the GENERATE option, the default setting is 'REPLACE EXISTING'. although this is OK, if you are modifying or adding new Display rules, it is very easy to forget to swap it to 'ADD AT END'. The Rep...
6 months ago in General 0 Needs review

Reference interactive add offset option

Need additional option under reference attachment dialog mode Interactive to specify offset. For example attaching OBJ it attaches to null origin by default.As alternative using attachment Top mode and XY= key-in it doesn't correctly set offset in...
6 months ago in General 0 Needs review

add the ability to define a level within a text style

In a text style you can define lots of attributes but not a level. It is possible to define a level in a dimension style, why not in a text style?
about 3 years ago in General 2 Needs review

Surface/volume unit decoration

Hi, When you are measuring a surface or a volume (in the metric system) the general rule is to add an exponant 2 (surface) or an exponant 3 (volume) to the unit you are using. In MicroStation (and all related software) when you are measuring a sur...
over 2 years ago in General 1 Needs review

Allow comma separated config variables to be semi-colon separated too

Allow variables that have multiple comma separated values also work with a semi-colon separator. Many variables store several values separated by a comma. For example MS_LEVEL_EDIT_ATTRIBUTE_LIST and MS_LEVEL_SYNC_ATTRIBUTE_LIST can have setti...
almost 2 years ago in General 1 Future consideration

copy item type from one element to another

As a user I'd like to copy an existing item type to one or more other graphicyl elements. Click the source element If multiple items are attached to the source element, the user can select/deselect item types click the target element The item type...
over 2 years ago in General 0 Needs review

SaveAs DWG Options: Merge Reference settings

In the Safe As DWG/DXF Options dialog box there is a Reference section in the General tab and there is a References tab. Settings in one place can influence the other. It makes much more sense to have all Reference Settings in one place. The setti...
almost 2 years ago in General 0 Needs review

add leader to existing note

Be able to add a leader to an existing note.
over 1 year ago in General 0 Future consideration