Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Pinned ideas

PINNED Support of wmts with restful protocol
WMTS tiles in Microstation are only supported in KVP, but not in RESTFUL. As a result, many wmts services cannot be used. There is an urgent need to integrate the restful protocol, as more and more public administration services are only offered v...

General

Showing 554

Associate Element Template with Ribbon Button

From the beginning of MicroStation CAD Managers have built custom tools and menus that do nothing more that set the correct symbology and start that corresponding tool.At first it was User Commands. Simple scripts that set correct level, color, we...
about 4 years ago in General 2 Needs review

AccuDraw Coordinate ACS-Display and Datapoint-Input integrated

This could greatly enhance Coordinate input and Datapoint Input.The AccuDraw Coordinate Display should show the "running" xyz-coordinates (active ACS) besides the cursor.This dialog could at the same time used (as a alternative for the separate di...
about 4 years ago in General 0 Needs review

[Text styles]Bring back Text justification=None

Justification=None which was available in earlier versions is gone and now opening older files it shows as Invalid. According to Bentley: in previous versions of MicroStation, the dropdown for the Justification property included "None" as an optio...
about 4 years ago in General 0 Needs review

Reference Attachment Settings Variable allow DEFAULT LEVEL control

MS_REF_DEFAULTSETTINGS control most of the reference attachmetn settings. But not one that I find very important: reference default level (see image) This defines the level of the reference, it is very important when exporting to dwg. If it is not...
6 months ago in General 0 Needs review

Publish queue of ideas that are being reviewed by the moderator

Prevents users having to guess or check if their ideas have been published.
6 months ago in General 0 Needs review

Surface/volume unit decoration

Hi, When you are measuring a surface or a volume (in the metric system) the general rule is to add an exponant 2 (surface) or an exponant 3 (volume) to the unit you are using. In MicroStation (and all related software) when you are measuring a sur...
over 2 years ago in General 1 Needs review

Ability to change the units of slope in the measure distance tool for Bentley View

It would be really useful to be able to change the units of 'Slope' in the measure distance tool e.g. to % and ratio (1:X).
about 1 year ago in General 0 Needs review

[Data cleanup] duplicates

Add option to delete both duplicates found in file. This would be useful to merge two different files and leave only those elements which have been changed. For example design history provides similar option to see changes but if it was not enable...
over 1 year ago in General 2 Needs review

Improve "Extend Line"

ToolBox "Modify" has the button "Extend Line". It would be interesting if in the tool settings dialog of this tool had new parameters such as: Distance (combobox): Increment (current) Percentage (%) Total length For example, AutoCAD has a command ...
over 3 years ago in General 0 Needs review

Configuration Explorer -> WorkSpace/WorkSet/Personal.ucf

Hello Bentley, I am using Configuration Explorer, but I notice it does not traverse Personal.ucf? Unless I am missing something could a near future upgrade include scanning WorkSpace/WorkSet/Personal.ucf? or could it continue to traverse the struc...
about 1 year ago in General 0 Needs review